20-Point Dual-Fuel Health & Safety Checklist
- Visual inspection of outdoor heat-pump & indoor furnace/AHU
- Power quality, earthing, surge protection; terminal tightening
- Thermostat/PCB diagnostics; outdoor sensor read & time/region
- Static pressure & CFM per ton across system; duct leakage scan
- Return/supply delta-T in cooling and heating
- Evaporator & condenser coil hygiene; fin straightening where needed
- Refrigerant leak suspicion test; nitrogen pressure test if indicated
- Deep evacuation to microns; charge by weight/SH/SC
- Defrost cycle validation & quiet mode setup (heat pump)
- Burner/igniter/flame sensor clean & test (furnace)
- Gas line leak test (soap/bubble/electronic sniffer)
- Manifold pressure & gas valve operation per manufacturer spec
- Combustion air & venting checks; draft test
- Heat-exchanger visual & temperature rise within spec
- Flue/termination integrity; slope/clearances; condensate management
- Condensing furnace condensate trap & neutraliser inspection
- Blower/inducer motor amperage, bearings & vibration
- Filter condition; MERV upgrade feasibility & pressure impact
- Dual-fuel switchover/lockout temperature & staging logic test
- CO alarm presence/check; final readings, notes & safety advisory
What We Do
Breakdown diagnostics & repair
no heat/cool, frequent trips, icing, lockouts, sensor/thermistor faults, PCB/inverter issues, compressor/fan failures, inducer/blower faults, igniter/flame sensor errors, gas valve problemsCombustion service
burner/igniter/flame sensor cleaning, manifold pressure set per spec, combustion air checks, draft test, heat-exchanger visual, CO safety checksRefrigeration & airflow
nitrogen-purged brazing, deep evacuation to microns, charge by weight/SH/SC, superheat/subcool validation, static pressure & CFM per ton balancingControls & switchover
dual-fuel thermostat setup, outdoor sensor, lockout temperature, staging/time delays, defrost strategy, BMS handshakesDuct & IAQ fixes
leakage testing & UL-181 sealing, insulation repairs, grille/diffuser sizing, MERV-11/13 filter upgrades, ERV/HRV fresh-air (where applicable)Installation/retrofit
load calculation, duct audit, coil selection, furnace sizing, gas piping sizing/pressure test, flue/chimney works, condensate neutraliser (for condensing furnaces), electrical protectionsRe-commissioning & optimisation
balance point tuning (tariff/weather), comfort curves, fan profiles, energy health reportAMC
scheduled service, priority response, combustion analysis, firmware/controls review